Bulbs Flower Basics Flower Beds & Specialty Gardens Flower Garden Garden Furniture Garden Gnomes Garden Seeds Garden Sheds Garden Statues Garden Tools & Supplies Gardening Basics Green & Organic Groundcovers & Vines Growing Annuals Growing Basil Growing Beans Growing Berries Growing Blueberries Growing Cactus Growing Corn Growing Cotton Growing Edibles Growing Flowers Growing Garlic Growing Grapes Growing Grass Growing Herbs Growing Jasmine Growing Mint Growing Mushrooms Orchids Growing Peanuts Growing Perennials Growing Plants Growing Rosemary Growing Roses Growing Strawberries Growing Sunflowers Growing Thyme Growing Tomatoes Growing Tulips Growing Vegetables Herb Basics Herb Garden Indoor Growing Landscaping Basics Landscaping Patios Landscaping Plants Landscaping Shrubs Landscaping Trees Landscaping Walks & Pathways Lawn Basics Lawn Maintenance Lawn Mowers Lawn Ornaments Lawn Planting Lawn Tools Outdoor Growing Overall Landscape Planning Pests, Weeds & Problems Plant Basics Rock Garden Rose Garden Shrubs Soil Specialty Gardens Trees Vegetable Garden Yard Maintenance

How to Troubleshoot a Kohler Fuel Solenoid

How to Start Lemon Seeds Indoors - watch on youtube
How to Troubleshoot a Kohler Fuel Solenoid

How to Troubleshoot a Kohler Fuel Solenoid. Backfiring is a startling explosive sound that can happen when you shut down your lawn mower or other small-engine-powered equipment. Fuel shutoff solenoids prevent engines, including the Kohler brand, from backfiring. By effectively blocking fuel flow to the carburetor when the ignition key switches to...

Backfiring is a startling explosive sound that can happen when you shut down your lawn mower or other small-engine-powered equipment. Fuel shutoff solenoids prevent engines, including the Kohler brand, from backfiring. By effectively blocking fuel flow to the carburetor when the ignition key switches to the "Off" position, excess fuel can't enter the combustion chamber, eliminating the potential for that annoying noise. If backfire still occurs, the fuel shutoff solenoid is suspect and requires investigation.
Things You'll Need
Volt-Ohm meter
Lower the throttle to the mid-range position just before shutting the Kohler engine down. In order for the fuel shutoff valve to work properly, the throttle position should be in the full to mid-range position. If a backfire occurs despite following the proper shutdown procedures, check for proper voltage.
Test for a minimum of 7 Volts DC at the fuel solenoid terminal using a Volt-Ohm meter. Place one of the meter leads to the solenoids terminal, and the second lead to the engine case. Power from the battery shuts the fuel flow off to the carburetor. No power is present on the solenoid while the engine is running. If no (or low) voltage is present at the solenoid, check the battery for proper charge and for good battery connection.
Test the battery for voltage using the Volt-Ohm meter. Attach the Volt-Ohm meter across the positive and negative battery posts while the engine is shut down. Crank the engine and observe the voltage drop across the battery posts. If the voltage drops below 9 Volts DC, apply a battery charger and bring the battery back to its appropriate charge. Replace the battery if it will not accept a charge.
Remove the fuel shutoff solenoid from the carburetor for further testing if the above tests reveal no problems. Connect 12 Volts DC power to the solenoid. Connect the negative (ground) lead to the solenoid case, and apply the positive (red) lead to the solenoid terminal. If the solenoid does not shift to the "Off" position, the solenoid is bad and replacement is necessary.
Tips & Warnings
Check the fuel supply and fuel filter if engine fails to start before troubleshooting the fuel shutoff solenoid.
Use extreme caution when working around fuel and a battery source--even a small spark will ignite the fuel.