Bulbs Flower Basics Flower Beds & Specialty Gardens Flower Garden Garden Furniture Garden Gnomes Garden Seeds Garden Sheds Garden Statues Garden Tools & Supplies Gardening Basics Green & Organic Groundcovers & Vines Growing Annuals Growing Basil Growing Beans Growing Berries Growing Blueberries Growing Cactus Growing Corn Growing Cotton Growing Edibles Growing Flowers Growing Garlic Growing Grapes Growing Grass Growing Herbs Growing Jasmine Growing Mint Growing Mushrooms Orchids Growing Peanuts Growing Perennials Growing Plants Growing Rosemary Growing Roses Growing Strawberries Growing Sunflowers Growing Thyme Growing Tomatoes Growing Tulips Growing Vegetables Herb Basics Herb Garden Indoor Growing Landscaping Basics Landscaping Patios Landscaping Plants Landscaping Shrubs Landscaping Trees Landscaping Walks & Pathways Lawn Basics Lawn Maintenance Lawn Mowers Lawn Ornaments Lawn Planting Lawn Tools Outdoor Growing Overall Landscape Planning Pests, Weeds & Problems Plant Basics Rock Garden Rose Garden Shrubs Soil Specialty Gardens Trees Vegetable Garden Yard Maintenance

How to Troubleshoot a Lawn Genie Sprinkler Valve

How to Start Lemon Seeds Indoors - watch on youtube
How to Troubleshoot a Lawn Genie Sprinkler Valve

How to Troubleshoot a Lawn Genie Sprinkler Valve. The Lawn Genie 54000 automatic sprinkler valve interfaces with a Lawn Genie timer or console, controlling water flow to underground sprinkler circuits. The 54000 supplies 5 to 20 gallons per minute at an operating pressure of 10 to 150 psi. Its valve solenoid operates on 19- to 24-volt input from...

The Lawn Genie 54000 automatic sprinkler valve interfaces with a Lawn Genie timer or console, controlling water flow to underground sprinkler circuits. The 54000 supplies 5 to 20 gallons per minute at an operating pressure of 10 to 150 psi. Its valve solenoid operates on 19- to 24-volt input from the timer or controller. Cable length from controller to valve can be up to 800 feet for 18-gauge multi-conductor wire or up to 2,000 feet for 14-gauge wire. Problems in Lawn Genie sprinkler valves can usually be isolated to either the timer or the valve solenoid.
Things You'll Need
Screwdriver
Voltmeter
Timer Does Not Open Valve
Manually open the valve handle, and determine if water is flowing into the circuit.
Use a voltmeter to check for voltage at the valve solenoid. If the valve solenoid is getting voltage from the timer but not opening, replace the solenoid.
Check for voltage at the output terminals of the timer. If there is voltage at the timer but no voltage at the solenoid, replace the multi-conductor sprinkler cable. If there is no voltage at the timer output terminals, replace the timer.
Valve Does Not Open Manually
Determine whether water is reaching the valve. Open the bleed screw at the valve to see if water spurts out. If there is no bleed screw, unscrew the solenoid slowly and look for water leaking.
Make sure the main water shutoff valve is open.
Make sure the flow control on the valve is open.
Replace the valve, if none of the above actions remedies the problem.
Valve Does Not Shut Off
Disconnect one of the cable conductors from the timer. If the valves closes, evaluate problems in the timer.
Turn off the water supply.
Unscrew the top of the valve, and remove the diaphragm.
Turn on the water supply, and flush the system for 15 seconds. Examine the diaphragm for defects.
Remove the solenoid, and clean any debris or obstructions from its ports. Reassemble the valve, and turn on the water.
Valve Does Not Completely Shut Off
Unscrew the top of the valve, and remove the diaphragm.
Turn on the water supply, and flush the system for 15 seconds. Examine the diaphragm for defects.
Remove the solenoid, and clean any debris or obstructions from its ports. Reassemble the valve, and turn on the water.
Valve Leaks At the Cap
Locate the highest sprinkler head in the circuit, and measure its elevation above ground.
Measure the elevation of the valve cap above ground.
Make sure the valve cap is at least 6 inches higher than the highest sprinkler head in the circuit, to prevent siphoning.